TEKLİF İSTE
RLK39-55-Z/31/35/40a/116  Kübik AC/DC Besleme, Zaman Ayarlı, 17m Algılama, Röle Çıkış, Terminal Bağlantı, Polarize Reflektörlü Fotoelektrik Sensör
0,00TL
KDV Hariç: 0,00TL
- Stok Durumu: Var
 - Marka: Pepperl Fuchs
 - Ürün Kodu: RLK39-55-Z/31/35/40a/116
 
Ücretsiz Kargo
10.000TL Üzeri Kargo Bedava
Banka Havalesi
Banka havalesinde ekstra %4 indirim imkanı
Hızlı Teslimat
Maksimum 2 İş Günü İçinde Kargoya Verilir
Güvenli Alışveriş
256BİT SSL Sertifikası ile Koruma
| Ürün Açıklaması | ||
|---|---|---|
| Retroreflective sensor without polarization filter | ||
| General specifications | ||
|---|---|---|
| Effective detection range | 0 ... 17 m | |
| Reflector distance | 0.1 ... 17 m | |
| Threshold detection range | 20 m | |
| Reference target | H50 reflector | |
| Light source | LED red | |
| Light type | modulated visible red light | |
| Polarization filter | no | |
| Ambient light limit | IEC / EN 60947-5-2 , 10000 Lux | |
| Functional safety related parameters | ||
| MTTFd | 803 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Function indicator | LED yellow: switching state LED red: pre-fault indication  | |
| Control elements | Sensing range adjuster, light-on/dark-on changeover switch | |
| Control elements | switch for timer function | |
| Electrical specifications | ||
| Operating voltage | 12 ... 240 V DC  24 ... 240 V AC (50 ... 60 Hz)  | |
| Ripple | 10 % | |
| No-load supply current | ≤ 50 mA | |
| Protection class | II,  rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution! The protection class 2 is only valid when the terminal compartment is closed. output circuit has basic insulation to control circuit according to IEC/EN 61140  | |
| Power consumption | ≤ 3 VA | |
| Time delay before availability | ≤ 300 ms | |
| Output | ||
| Switching type | light/dark on | |
| Signal output | 1 relay output | |
| Switching voltage | max. 240 V AC ; 150 V DC | |
| Switching current | max. 3 A | |
| Switching power | DC: max. 90 W AC: max. 750 VA | |
| Switching frequency | ≤ 25 Hz | |
| Response time | ≤ 20 ms | |
| Timer function | On-/off-delay or pulse extension on choice | |
| Compliance with standards and directives | ||
| Directive conformity | EMC Directive 2004/108/EC | |
| EMC Directive 2004/108/EC | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007+A1:2012 | |
| Standard conformity | ||
| Product standard | EN 60947-5-2:2007  IEC 60947-5-2:2007  | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011  TR CU 004/2011  | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Approvals | CE | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 55 °C (-13 ... 131 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Housing width | 25 mm | |
| Housing height | 64 mm | |
| Housing depth | 75 mm | |
| Degree of protection | IP67 | |
| Connection | terminal compartment PG9, ≤ 2.5 mm2 | |
| Material | ||
| Housing | PBT | |
| Optical face | PMMA | |
| Mass | approx. 110 g | |
| General information | ||
| Scope of delivery | Mounting aid , Reflector | |
| General specifications | ||
|---|---|---|
| Effective detection range | 0 ... 17 m | |
| Reflector distance | 0.1 ... 17 m | |
| Threshold detection range | 20 m | |
| Reference target | H50 reflector | |
| Light source | LED red | |
| Light type | modulated visible red light | |
| Polarization filter | no | |
| Ambient light limit | IEC / EN 60947-5-2 , 10000 Lux | |
| Functional safety related parameters | ||
| MTTFd | 803 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Function indicator | LED yellow: switching state LED red: pre-fault indication  | |
| Control elements | Sensing range adjuster, light-on/dark-on changeover switch | |
| Control elements | switch for timer function | |
| Electrical specifications | ||
| Operating voltage | 12 ... 240 V DC  24 ... 240 V AC (50 ... 60 Hz)  | |
| Ripple | 10 % | |
| No-load supply current | ≤ 50 mA | |
| Protection class | II,  rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution! The protection class 2 is only valid when the terminal compartment is closed. output circuit has basic insulation to control circuit according to IEC/EN 61140  | |
| Power consumption | ≤ 3 VA | |
| Time delay before availability | ≤ 300 ms | |
| Output | ||
| Switching type | light/dark on | |
| Signal output | 1 relay output | |
| Switching voltage | max. 240 V AC ; 150 V DC | |
| Switching current | max. 3 A | |
| Switching power | DC: max. 90 W AC: max. 750 VA | |
| Switching frequency | ≤ 25 Hz | |
| Response time | ≤ 20 ms | |
| Timer function | On-/off-delay or pulse extension on choice | |
| Compliance with standards and directives | ||
| Directive conformity | EMC Directive 2004/108/EC | |
| EMC Directive 2004/108/EC | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007+A1:2012 | |
| Standard conformity | ||
| Product standard | EN 60947-5-2:2007  IEC 60947-5-2:2007  | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011  TR CU 004/2011  | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Approvals | CE | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 55 °C (-13 ... 131 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Housing width | 25 mm | |
| Housing height | 64 mm | |
| Housing depth | 75 mm | |
| Degree of protection | IP67 | |
| Connection | terminal compartment PG9, ≤ 2.5 mm2 | |
| Material | ||
| Housing | PBT | |
| Optical face | PMMA | |
| Mass | approx. 110 g | |
| General information | ||
| Scope of delivery | Mounting aid , Reflector | |