Ürün Açıklaması | ||
---|---|---|
Robust, compact, long range photoelectric sensors for detecting people, objects and vehicles |
General specifications | ||
---|---|---|
Effective detection range | 0 ... 12 m | |
Reflector distance | 0.04 ... 12 m | |
Threshold detection range | 14 m | |
Reference target | reflector C110-2 Diameter: 84 mm , included with delivery | |
Light source | LED | |
Light type | modulated visible red light , 640 nm | |
Diameter of the light spot | approx. 35 mm at a distance of 12 m | |
Angle of divergence | ± 1 ° | |
Ambient light limit | 90000 Lux | |
Functional safety related parameters | ||
MTTFd | 1460 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | LED red illuminates: when beam is free flashes: when level falls below function reserve off: when beam is interrupted | |
Electrical specifications | ||
Operating voltage | 24 ... 230 V AC/DC | |
Ripple | 10 % | |
No-load supply current | ≤ 8.5 mA | |
Power consumption | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA | |
Output | ||
Switching type | light on | |
Signal output | Relay, 1 alternator | |
Switching voltage | 230 V AC | |
Switching current | max. 2 A | |
Switching frequency | 7 Hz | |
Response time | 50 ms | |
Compliance with standards and directives | ||
Standard conformity | ||
Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
CE conformity | yes | |
EAC conformity | TR CU 020/2011 TR CU 004/2011 | |
UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | terminal compartment | |
Material | ||
Housing | Plastic ABS, flame resistant | |
Optical face | plastic | |
Mass | approx. 200 g | |
Note | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
General specifications | ||
---|---|---|
Effective detection range | 0 ... 12 m | |
Reflector distance | 0.04 ... 12 m | |
Threshold detection range | 14 m | |
Reference target | reflector C110-2 Diameter: 84 mm , included with delivery | |
Light source | LED | |
Light type | modulated visible red light , 640 nm | |
Diameter of the light spot | approx. 35 mm at a distance of 12 m | |
Angle of divergence | ± 1 ° | |
Ambient light limit | 90000 Lux | |
Functional safety related parameters | ||
MTTFd | 1460 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | LED red illuminates: when beam is free flashes: when level falls below function reserve off: when beam is interrupted | |
Electrical specifications | ||
Operating voltage | 24 ... 230 V AC/DC | |
Ripple | 10 % | |
No-load supply current | ≤ 8.5 mA | |
Power consumption | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA | |
Output | ||
Switching type | light on | |
Signal output | Relay, 1 alternator | |
Switching voltage | 230 V AC | |
Switching current | max. 2 A | |
Switching frequency | 7 Hz | |
Response time | 50 ms | |
Compliance with standards and directives | ||
Standard conformity | ||
Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
CE conformity | yes | |
EAC conformity | TR CU 020/2011 TR CU 004/2011 | |
UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | terminal compartment | |
Material | ||
Housing | Plastic ABS, flame resistant | |
Optical face | plastic | |
Mass | approx. 200 g | |
Note | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |