Ürün Açıklaması | ||
---|---|---|
Retroreflective area sensor with 6 beams in a widely used standard photoelectric housing, red light, 4 m detection range, light/dark on switchable, push-pull output, fixed cable with M12 plug |
General specifications | ||
---|---|---|
Effective detection range | 0 ... 4 m | |
Reflector distance | Reflector A80: 0.4 ... 4 m , H85-2 reflector: 0.2 ... 4 m , Foil reflector OFR-100/100: 0.4 ... 3 m | |
Threshold detection range | 5.6 m | |
Sensing range | typical 60 mm , Object has to cover the refelector completely in one dimension | |
Reference target | Reflector A80 H85-2 reflector Foil reflector OFR-100/100 | |
Light source | LED | |
Light type | modulated visible red light , 625 nm | |
Polarization filter | yes | |
Number of beams | 6 | |
Diameter of the light spot | approx. 220 mm at detection range 4 m | |
Angle of divergence | +/- 2.5 ° | |
Ambient light limit | 5000 Lux | |
Resolution | 12 mm | |
Functional safety related parameters | ||
MTTFd | 310 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green, statically lit Power on Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) short-circuit : LED green flashing (approx. 4 Hz) | |
Function indicator | 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted Teach-In : LED yellow/green; equiphase flashing; 2,5 Hz Changeover signal tracking: LED yellow, 1 Hz flashing / 2x flashing | |
Control elements | rotary switch for light/dark , Teach-In key | |
Electrical specifications | ||
Operating voltage | 12 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | max. 50 mA | |
Output | ||
Switching type | light/dark on, switchable | |
Signal output | 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA | |
Voltage drop | ≤ 2.5 V DC | |
Switching frequency | 230 Hz | |
Response time | 1 ms | |
Conformity | ||
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
UL approval | cULus Listed, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) -10 ... 40 °C (14 ... 104 °F) for inactive signal tracking | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Housing width | 25.8 mm | |
Housing height | 88 mm | |
Housing depth | 54.3 mm | |
Degree of protection | IP67 | |
Connection | 300 mm fixed cable with M12 x 1, 4-pin connector | |
Material | ||
Housing | Plastic ABS | |
Optical face | Plastic pane | |
Mass | 100 g |
General specifications | ||
---|---|---|
Effective detection range | 0 ... 4 m | |
Reflector distance | Reflector A80: 0.4 ... 4 m , H85-2 reflector: 0.2 ... 4 m , Foil reflector OFR-100/100: 0.4 ... 3 m | |
Threshold detection range | 5.6 m | |
Sensing range | typical 60 mm , Object has to cover the refelector completely in one dimension | |
Reference target | Reflector A80 H85-2 reflector Foil reflector OFR-100/100 | |
Light source | LED | |
Light type | modulated visible red light , 625 nm | |
Polarization filter | yes | |
Number of beams | 6 | |
Diameter of the light spot | approx. 220 mm at detection range 4 m | |
Angle of divergence | +/- 2.5 ° | |
Ambient light limit | 5000 Lux | |
Resolution | 12 mm | |
Functional safety related parameters | ||
MTTFd | 310 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green, statically lit Power on Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) short-circuit : LED green flashing (approx. 4 Hz) | |
Function indicator | 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted Teach-In : LED yellow/green; equiphase flashing; 2,5 Hz Changeover signal tracking: LED yellow, 1 Hz flashing / 2x flashing | |
Control elements | rotary switch for light/dark , Teach-In key | |
Electrical specifications | ||
Operating voltage | 12 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | max. 50 mA | |
Output | ||
Switching type | light/dark on, switchable | |
Signal output | 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA | |
Voltage drop | ≤ 2.5 V DC | |
Switching frequency | 230 Hz | |
Response time | 1 ms | |
Conformity | ||
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
UL approval | cULus Listed, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) -10 ... 40 °C (14 ... 104 °F) for inactive signal tracking | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Housing width | 25.8 mm | |
Housing height | 88 mm | |
Housing depth | 54.3 mm | |
Degree of protection | IP67 | |
Connection | 300 mm fixed cable with M12 x 1, 4-pin connector | |
Material | ||
Housing | Plastic ABS | |
Optical face | Plastic pane | |
Mass | 100 g |