TEKLİF İSTE
SJ3,5-S1N 3,5mm Çatal Aralığı, Namur Çıkışlı, SIL 3 Onaylı, Endüktif Sensör
0,00TL
KDV Hariç: 0,00TL
- Stok Durumu: Var
- Marka: Pepperl Fuchs
- Ürün Kodu: SJ3,5-S1N
Ücretsiz Kargo
10.000TL Üzeri Kargo Bedava
Banka Havalesi
Banka havalesinde ekstra %4 indirim imkanı
Hızlı Teslimat
Maksimum 2 İş Günü İçinde Kargoya Verilir
Güvenli Alışveriş
256BİT SSL Sertifikası ile Koruma
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NAMUR with safety function | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Reference target | 10 x 7 x 0.3 mm3, Al | |
| Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V | |
| Switching frequency | 0 ... 2500 Hz | |
| Hysteresis | with NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.05 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1) | |
| Suitable for 2:1 technology | yes , with reverse polarity protection diode | |
| Rate of current rise | 2.1 mA / mm | |
| Current consumption | ||
| Measuring plate not detected | 0.2 ... 1 mA | |
| Measuring plate detected | ≥ 3 mA | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| MTTFd | 11850 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
| Approvals and certificates | ||
| EAC conformity | TR CU 012/2011 | |
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads LiY , 500 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Note | only for non-ferrous metal Adjustable stop | |
| Data for application in connection with hazardous areas | ||
| Equipment protection level | Ga , Gb , Gc (ic) , Da , Mb | |
| Equipment protection level Ga | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02585A*] | |
| Certificates | ||
| Appropriate type | SJ3,5-S1N... | |
| ATEX certificate | PTB 00 ATEX 2049 X | |
| ATEX marking | II 1G Ex ia IIC T6...T1 Ga | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| IECEx certificate | IECEx PTB 11.0092X | |
| IECEx marking | Ex ia IIC T6...T1 Ga | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 100 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. | |
| for ATEX | at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 56 °C (132.8 °F) T5 : 68 °C (154.4 °F) T4 : 96 °C (204.8 °F) T3 : 96 °C (204.8 °F) T2 : 96 °C (204.8 °F) T1 : 96 °C (204.8 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 49 °C (120.2 °F) T5 : 61 °C (141.8 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 28 °C (82.4 °F) T5 : 40 °C (104 °F) T4 : 68 °C (154.4 °F) T3 : 68 °C (154.4 °F) T2 : 68 °C (154.4 °F) T1 : 68 °C (154.4 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 13 °C (55.4 °F) T5 : 25 °C (77 °F) T4 : 53 °C (127.4 °F) T3 : 53 °C (127.4 °F) T2 : 53 °C (127.4 °F) T1 : 53 °C (127.4 °F) | |
| for IECEx | at Ui = 16 V , Ii = 25 mA 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) | |
| Equipment protection level Gb | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02585A*] | |
| Certificates | ||
| Appropriate type | SJ3,5-S1N... | |
| ATEX certificate | PTB 00 ATEX 2049 X | |
| ATEX marking | II 1G Ex ia IIC T6…T1 Ga | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| IECEx certificate | IECEx PTB 11.0092X | |
| IECEx marking | Ex ia IIC T6...T1 Ga | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 100 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) | |
| Equipment protection level Gc (ic) | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02586A*] | |
| Certificates | ||
| ATEX certificate | PF 13 CERT 2895 X | |
| ATEX marking | II 3G Ex ic IIC T6…T1 Gc | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 100 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 20 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) | |
| Equipment protection level Da | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02585A*] | |
| Certificates | ||
| Appropriate type | SJ3,5-S1N... | |
| ATEX certificate | PTB 00 ATEX 2049 X | |
| ATEX marking | II 1D Ex ia IIIC T135°C Da | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| IECEx certificate | IECEx PTB 11.0092X | |
| IECEx marking | Ex ia IIIC T135°C Da | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 30 nF ; a cable length of 10 m is considered. | |
| Effective internal inductance | max. 100 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 °C (165.2 °F) | |
| Equipment protection level Mb | ||
| Type of protection | intrinsic safety | |
| Certificates | ||
| Appropriate type | SJ3,5-S1N... | |
| IECEx certificate | IECEx PTB 11.0092X | |
| IECEx marking | Ex ia I Mb | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 100 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 °C (165.2 °F) | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Manuals | Dil | Dosya Tipi | Dosya Boyutu |
|---|---|---|---|
| Functional Safety Manual | ENG | 507 KB | |
| Handbuch Funktionale Sicherheit | GER | 512 KB | |
| Instruction manuals | |||
| Инструкции | BUL | 141 KB | |
| Návod k poużití | CZE | 135 KB | |
| Instruktions manual | DAN | 134 KB | |
| Instruction manual | ENG | 141 KB | |
| Kasutusjuhend | EST | 130 KB | |
| Käyttöohje | FIN | 130 KB | |
| Manuel d'instructions | FRA | 138 KB | |
| Betriebsanleitung | GER | 141 KB | |
| Οδηγίες χρήσης | GRE | 145 KB | |
| Handleiding | HOL | 135 KB | |
| Instruction manual / Betriebsanleitung | HRV | 134 KB | |
| Használati útmutató | HUN | 138 KB | |
| Manuale di istruzioni | ITA | 135 KB | |
| Lietošanas pamācība | LAV | 134 KB | |
| Instrukciju vadovas | LIT | 135 KB | |
| Instrukcja obsługi | POL | 138 KB | |
| Manual de instruções | POR | 136 KB | |
| Manual de utilizare | RON | 136 KB | |
| Návod na poużitie | SLK | 135 KB | |
| Navodila za uporabo | SLV | 133 KB | |
| Manual de instrucciones | SPA | 136 KB | |
| Manual | SWE | 133 KB | |
| Manuals | Dil | Dosya Tipi | Dosya Boyutu |
|---|---|---|---|
| Functional Safety Manual | ENG | 507 KB | |
| Handbuch Funktionale Sicherheit | GER | 512 KB | |
| Instruction manuals | |||
| Инструкции | BUL | 141 KB | |
| Návod k poużití | CZE | 135 KB | |
| Instruktions manual | DAN | 134 KB | |
| Instruction manual | ENG | 141 KB | |
| Kasutusjuhend | EST | 130 KB | |
| Käyttöohje | FIN | 130 KB | |
| Manuel d'instructions | FRA | 138 KB | |
| Betriebsanleitung | GER | 141 KB | |
| Οδηγίες χρήσης | GRE | 145 KB | |
| Handleiding | HOL | 135 KB | |
| Instruction manual / Betriebsanleitung | HRV | 134 KB | |
| Használati útmutató | HUN | 138 KB | |
| Manuale di istruzioni | ITA | 135 KB | |
| Lietošanas pamācība | LAV | 134 KB | |
| Instrukciju vadovas | LIT | 135 KB | |
| Instrukcja obsługi | POL | 138 KB | |
| Manual de instruções | POR | 136 KB | |
| Manual de utilizare | RON | 136 KB | |
| Návod na poużitie | SLK | 135 KB | |
| Navodila za uporabo | SLV | 133 KB | |
| Manual de instrucciones | SPA | 136 KB | |
| Manual | SWE | 133 KB | |



II 1G Ex ia IIC T6...T1 Ga