| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 10 mm | |
| Depth of immersion (lateral) | 13.5 ... 16.5 mm , typ. 15 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 0.1 ... 0.5 mm | |
| Current consumption | ||
| Measuring plate not detected | ≥ 3 mA at nominal voltage | |
| Measuring plate detected | ≤ 1 mA at nominal voltage | |
| Functional safety related parameters | ||
| MTTFd | 11460 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.75 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Data for application in connection with hazardous areas | ||
| Equipment protection level | Ga , Gb , Da , Mb | |
| Equipment protection level Ga | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02585A*] | |
| Certificates | ||
| Appropriate type | SJ10-N... | |
| ATEX certificate | PTB 99 ATEX 2219 X | |
| ATEX marking | II 1G Ex ia IIC T6...T1 Ga | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| IECEx certificate | IECEx PTB 11.0091X | |
| IECEx marking | Ex ia IIC T6...T1 Ga | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 50 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 1000 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. | |
| for ATEX | at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 55 °C (131 °F) T5 : 67 °C (152.6 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 48 °C (118.4 °F) T5 : 60 °C (140 °F) T4 : 88 °C (190.4 °F) T3 : 88 °C (190.4 °F) T2 : 88 °C (190.4 °F) T1 : 88 °C (190.4 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 25 °C (77 °F) T5 : 37 °C (98.6 °F) T4 : 65 °C (149 °F) T3 : 65 °C (149 °F) T2 : 65 °C (149 °F) T1 : 65 °C (149 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 9 °C (48.2 °F) T5 : 21 °C (69.8 °F) T4 : 49 °C (120.2 °F) T3 : 49 °C (120.2 °F) T2 : 49 °C (120.2 °F) T1 : 49 °C (120.2 °F) | |
| for IECEx | at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 72 °C (161.6 °F) T5 : 87 °C (188.6 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 42 °C (107.6 °F) T5 : 57 °C (134.6 °F) T4 : 82 °C (179.6 °F) T3 : 82 °C (179.6 °F) T2 : 82 °C (179.6 °F) T1 : 82 °C (179.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 26 °C (78.8 °F) T5 : 41 °C (105.8 °F) T4 : 63 °C (145.4 °F) T3 : 63 °C (145.4 °F) T2 : 63 °C (145.4 °F) T1 : 63 °C (145.4 °F) | |
| Equipment protection level Gb | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02585A*] | |
| Certificates | ||
| Appropriate type | SJ10-N... | |
| ATEX certificate | PTB 99 ATEX 2219 X | |
| ATEX marking | II 1G Ex ia IIC T6…T1 Ga | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| IECEx certificate | IECEx PTB 11.0091X | |
| IECEx marking | Ex ia IIC T6...T1 Ga | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 50 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 1000 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 72 °C (161.6 °F) T5 : 87 °C (188.6 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 42 °C (107.6 °F) T5 : 57 °C (134.6 °F) T4 : 82 °C (179.6 °F) T3 : 82 °C (179.6 °F) T2 : 82 °C (179.6 °F) T1 : 82 °C (179.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 26 °C (78.8 °F) T5 : 41 °C (105.8 °F) T4 : 63 °C (145.4 °F) T3 : 63 °C (145.4 °F) T2 : 63 °C (145.4 °F) T1 : 63 °C (145.4 °F) | |
| Equipment protection level Da | ||
| Type of protection | intrinsic safety | |
| CE marking | [*PD-Z02585A*] | |
| Certificates | ||
| Appropriate type | SJ10-N... | |
| ATEX certificate | PTB 99 ATEX 2219 X | |
| ATEX marking | II 1D Ex ia IIIC T135°C Da | |
| Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| IECEx certificate | IECEx PTB 11.0091X | |
| IECEx marking | Ex ia IIIC T135°C Da | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 50 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 1000 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 82 °C (179.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 63 °C (145.4 °F) | |
| Equipment protection level Mb | ||
| Type of protection | intrinsic safety | |
| Certificates | ||
| Appropriate type | SJ10-N... | |
| IECEx certificate | IECEx PTB 11.0091X | |
| IECEx marking | Ex ia I Mb | |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
| Effective internal capacitance | max. 50 nF A cable length of 10 m is considered. | |
| Effective internal inductance | max. 1000 µH A cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 82 °C (179.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 63 °C (145.4 °F) | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Instruction manuals | Dil | Dosya Tipi | Dosya Boyutu |
|---|---|---|---|
| Инструкции | BUL | 155 KB | |
| Návod k poużití | CZE | 148 KB | |
| Instruktions manual | DAN | 147 KB | |
| Instruction manual | ENG | 153 KB | |
| Kasutusjuhend | EST | 142 KB | |
| Käyttöohje | FIN | 143 KB | |
| Manuel d'instructions | FRA | 151 KB | |
| Betriebsanleitung | GER | 153 KB | |
| Οδηγίες χρήσης | GRE | 158 KB | |
| Handleiding | HOL | 148 KB | |
| Instruction manual / Betriebsanleitung | HRV | 147 KB | |
| Használati útmutató | HUN | 151 KB | |
| Manuale di istruzioni | ITA | 148 KB | |
| Lietošanas pamācība | LAV | 147 KB | |
| Instrukciju vadovas | LIT | 148 KB | |
| Instrukcja obsługi | POL | 151 KB | |
| Manual de instruções | POR | 150 KB | |
| Manual de utilizare | RON | 149 KB | |
| Návod na poużitie | SLK | 148 KB | |
| Navodila za uporabo | SLV | 146 KB | |
| Manual de instrucciones | SPA | 149 KB | |
| Manual | SWE | 146 KB |
| Instruction manuals | Dil | Dosya Tipi | Dosya Boyutu |
|---|---|---|---|
| Инструкции | BUL | 155 KB | |
| Návod k poużití | CZE | 148 KB | |
| Instruktions manual | DAN | 147 KB | |
| Instruction manual | ENG | 153 KB | |
| Kasutusjuhend | EST | 142 KB | |
| Käyttöohje | FIN | 143 KB | |
| Manuel d'instructions | FRA | 151 KB | |
| Betriebsanleitung | GER | 153 KB | |
| Οδηγίες χρήσης | GRE | 158 KB | |
| Handleiding | HOL | 148 KB | |
| Instruction manual / Betriebsanleitung | HRV | 147 KB | |
| Használati útmutató | HUN | 151 KB | |
| Manuale di istruzioni | ITA | 148 KB | |
| Lietošanas pamācība | LAV | 147 KB | |
| Instrukciju vadovas | LIT | 148 KB | |
| Instrukcja obsługi | POL | 151 KB | |
| Manual de instruções | POR | 150 KB | |
| Manual de utilizare | RON | 149 KB | |
| Návod na poużitie | SLK | 148 KB | |
| Navodila za uporabo | SLV | 146 KB | |
| Manual de instrucciones | SPA | 149 KB | |
| Manual | SWE | 146 KB |
| Algılama | |
| Mesafesi | 10 mm ... < 20 mm |
| Bağlantı. | |
| Prensibi | 2 Tel |
| Çıkış | |
| Fonksiyonu | (NC) |
| Gövde | |
| Materyali | Plastik |
| Kontrol | |
| Çıkış | Namur |
| Montaj | |
| Şekli | Kablolu |
| Voltaj | |
| Girişi | DC |



II 1G Ex ia IIC T6...T1 Ga