| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 8 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 6.48 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. % | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | ≤ 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
| Approvals and certificates | ||
| EAC conformity | TR CU 012/2011 | |
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.75 mm2 | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Equipment protection level Ga | ||
| CE marking | [*PD-Z02585A*] | |
| ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions | |
| Appropriate type | NJ 8-18GM-N... | |
| Effective internal capacitance | max. 70 nF ; a cable length of 10 m is considered. | |
| Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. | |
| Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
| Equipment protection level Gb | ||
| CE marking | [*PD-Z02585A*] | |
| ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions | |
| Appropriate type | NJ 8-18GM-N... | |
| Effective internal capacitance | max. 70 nF ; a cable length of 10 m is considered. | |
| Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
| Equipment protection level Da | ||
| CE marking | [*PD-Z02585A*] | |
| ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions | |
| Appropriate type | NJ 8-18GM-N... | |
| Effective internal capacitance | max. 70 nF ; a cable length of 10 m is considered. | |
| Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. | |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G; 2G; 1D | |
| Instruction manuals | Dil | Dosya Tipi | Dosya Boyutu |
|---|---|---|---|
| Instruction manual | ENG | 46 KB | |
| Manuel d'instructions | FRA | 46 KB | |
| Betriebsanleitung | GER | 49 KB | |
| Manuale di istruzioni | ITA | 43 KB | |
| Manual de instrucciones | SPA | 46 KB | |
| Technical information | |||
| Installation conditions | ENG | 191 KB | |
| Einbaubedingungen | GER | 194 KB | |
| warunki montażu | POL | 245 KB | |
| Условия монтажа | RUS | 274 KB | |
| Instruction manuals | Dil | Dosya Tipi | Dosya Boyutu |
|---|---|---|---|
| Instruction manual | ENG | 46 KB | |
| Manuel d'instructions | FRA | 46 KB | |
| Betriebsanleitung | GER | 49 KB | |
| Manuale di istruzioni | ITA | 43 KB | |
| Manual de instrucciones | SPA | 46 KB | |
| Technical information | |||
| Installation conditions | ENG | 191 KB | |
| Einbaubedingungen | GER | 194 KB | |
| warunki montażu | POL | 245 KB | |
| Условия монтажа | RUS | 274 KB | |
| Algılama | |
| Mesafesi | 5 mm ... < 10 mm |
| Bağlantı. | |
| Prensibi | 2 Tel |
| Çıkış | |
| Fonksiyonu | (NC) |
| Gövde | |
| Materyali | Metal |
| Kontrol | |
| Çıkış | Namur |
| Montaj | |
| Şekli | Kablolu |
| Özel | |
| Uygulama | Arttırılmış Sıcaklık |
| Şaft | |
| Gövde | M18 |
| Voltaj | |
| Girişi | DC |



II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label.