General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance1.5 mm
Installationflush
Assured operating distance0 ... 1.215 mm
Actual operating distance1.35 ... 1.65 mm typ.
Reduction factor rAl0.3
Reduction factor rCu0.2
Reduction factor r3040.7
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 2000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption 
 Measuring plate not detectedmin. 3 mA
 Measuring plate detected≤ 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd3590 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity 
 NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
 StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
EAC conformityTR CU 012/2011
FM approval 
 Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.14 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing faceLCP
Degree of protectionIP67
Cable 
 Bending radius> 10 x cable diameter
Equipment protection level Ga
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate typeNCB1,5...M...N0...
Effective internal capacitancemax. 90 nF ; a cable length of 10 m is considered.
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 1G Ex ia IIC T6…T1 Ga
The Ex-significant identification is on the enclosed adhesive label
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate typeNCB1,5...M...N0...
Effective internal capacitancemax. 90 nF ; a cable length of 10 m is considered.
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Gc (ic)
CertificatePF 13 CERT 2895 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3G Ex ic IIC T6…T1 Gc
The Ex-significant identification is on the enclosed adhesive label
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category "ic" Use is restricted to the following stated conditions
Effective internal capacitancemax. 90 nF ; a cable length of 10 m is considered.
Effective internal inductancemax. 100 µH ; A cable length of 10 m is considered.
Special conditions 
 for Pi=34 mW, Ii=25 mA, T655 °C (131 °F)
 for Pi=34 mW, Ii=25 mA, T555 °C (131 °F)
 for Pi=34 mW, Ii=25 mA, T4-T155 °C (131 °F)
 for Pi=64 mW, Ii=25 mA, T655 °C (131 °F)
 for Pi=64 mW, Ii=25 mA, T555 °C (131 °F)
 for Pi=64 mW, Ii=25 mA, T4-T155 °C (131 °F)
 for Pi=169 mW, Ii=52 mA, T641 °C (105.8 °F)
 for Pi=169 mW, Ii=52 mA, T541 °C (105.8 °F)
 for Pi=169 mW, Ii=52 mA, T4-T141 °C (105.8 °F)
 for Pi=242 mW, Ii=76 mA, T629 °C (84.2 °F)
 for Pi=242 mW, Ii=76 mA, T529 °C (84.2 °F)
 for Pi=242 mW, Ii=76 mA, T4-T129 °C (84.2 °F)
Equipment protection level Gc (nL)
Standard conformityEN 60079-15:2005 Ignition protection category "n"
Use is restricted to the following stated conditions
Effective internal capacitance Cimax. 90 nF ; a cable length of 10 m is considered.
Effective internal inductance Limax. 100 µH ; A cable length of 10 m is considered.
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
Special conditions 
 for Pi=34 mW, Ii=25 mA, T655 °C (131 °F)
 for Pi=34 mW, Ii=25 mA, T555 °C (131 °F)
 for Pi=34 mW, Ii=25 mA, T4-T155 °C (131 °F)
 for Pi=64 mW, Ii=25 mA, T655 °C (131 °F)
 for Pi=64 mW, Ii=25 mA, T555 °C (131 °F)
 for Pi=64 mW, Ii=25 mA, T4-T155 °C (131 °F)
 for Pi=169 mW, Ii=52 mA, T641 °C (105.8 °F)
 for Pi=169 mW, Ii=52 mA, T541 °C (105.8 °F)
 for Pi=169 mW, Ii=52 mA, T4-T141 °C (105.8 °F)
 for Pi=242 mW, Ii=76 mA, T629 °C (84.2 °F)
 for Pi=242 mW, Ii=76 mA, T529 °C (84.2 °F)
 for Pi=242 mW, Ii=76 mA, T4-T129 °C (84.2 °F)
Equipment protection level Da
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate typeNCB1,5...M...N0...
Effective internal capacitancemax. 90 nF ; a cable length of 10 m is considered.
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperature
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
General information
Use in the hazardous areasee instruction manuals
 Category1G; 2G; 3G; 1D
Instruction manualsDilDosya TipiDosya Boyutu
Instruction manualENGPDF47 KB
Manuel d'instructionsFRAPDF48 KB
BetriebsanleitungGERPDF51 KB
Manuale di istruzioniITAPDF45 KB
Manual de instruccionesSPAPDF47 KB
Technical information
Installation conditionsENGPDF191 KB
EinbaubedingungenGERPDF194 KB
warunki montażuPOLPDF245 KB
Условия монтажаRUSPDF274 KB
Instruction manualsDilDosya TipiDosya Boyutu
Instruction manualENGPDF47 KB
Manuel d'instructionsFRAPDF48 KB
BetriebsanleitungGERPDF51 KB
Manuale di istruzioniITAPDF45 KB
Manual de instruccionesSPAPDF47 KB
Technical information
Installation conditionsENGPDF191 KB
EinbaubedingungenGERPDF194 KB
warunki montażuPOLPDF245 KB
Условия монтажаRUSPDF274 KB
Algılama
Mesafesi< 3 mm
Bağlantı.
Prensibi2 Tel
Çıkış
Fonksiyonu(NC)
Gövde
MateryaliMetal
Kontrol
ÇıkışNamur
Montaj
ŞekliKablolu
Özel
UygulamaArttırılmış Sıcaklık
Şaft
GövdeM8
Voltaj
GirişiDC