| Robust, compact, long range photoelectric sensors for detecting people, objects and vehicles | ||
| General specifications | ||
|---|---|---|
| Effective detection range | 0 ... 12 m | |
| Reflector distance | 0.04 ... 12 m | |
| Threshold detection range | 14 m | |
| Reference target | reflector C110-2 Diameter: 84 mm , included with delivery | |
| Light source | LED | |
| Light type | modulated visible red light , 640 nm | |
| Diameter of the light spot | approx. 35 mm at a distance of 12 m | |
| Angle of divergence | ± 1 ° | |
| Ambient light limit | 90000 Lux | |
| Functional safety related parameters | ||
| MTTFd | 1460 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Function indicator | LED red illuminates: when beam is free flashes: when level falls below function reserve off: when beam is interrupted | |
| Electrical specifications | ||
| Operating voltage | 24 ... 230 V AC/DC | |
| Ripple | 10 % | |
| No-load supply current | ≤ 8.5 mA | |
| Power consumption | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA | |
| Output | ||
| Switching type | light on | |
| Signal output | Relay, 1 alternator | |
| Switching voltage | 230 V AC | |
| Switching current | max. 2 A | |
| Switching frequency | 7 Hz | |
| Response time | 50 ms | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| CE conformity | yes | |
| EAC conformity | TR CU 020/2011 TR CU 004/2011 | |
| UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | terminal compartment | |
| Material | ||
| Housing | Plastic ABS, flame resistant | |
| Optical face | plastic | |
| Mass | approx. 200 g | |
| Note | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| General specifications | ||
|---|---|---|
| Effective detection range | 0 ... 12 m | |
| Reflector distance | 0.04 ... 12 m | |
| Threshold detection range | 14 m | |
| Reference target | reflector C110-2 Diameter: 84 mm , included with delivery | |
| Light source | LED | |
| Light type | modulated visible red light , 640 nm | |
| Diameter of the light spot | approx. 35 mm at a distance of 12 m | |
| Angle of divergence | ± 1 ° | |
| Ambient light limit | 90000 Lux | |
| Functional safety related parameters | ||
| MTTFd | 1460 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Function indicator | LED red illuminates: when beam is free flashes: when level falls below function reserve off: when beam is interrupted | |
| Electrical specifications | ||
| Operating voltage | 24 ... 230 V AC/DC | |
| Ripple | 10 % | |
| No-load supply current | ≤ 8.5 mA | |
| Power consumption | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA | |
| Output | ||
| Switching type | light on | |
| Signal output | Relay, 1 alternator | |
| Switching voltage | 230 V AC | |
| Switching current | max. 2 A | |
| Switching frequency | 7 Hz | |
| Response time | 50 ms | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| CE conformity | yes | |
| EAC conformity | TR CU 020/2011 TR CU 004/2011 | |
| UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | terminal compartment | |
| Material | ||
| Housing | Plastic ABS, flame resistant | |
| Optical face | plastic | |
| Mass | approx. 200 g | |
| Note | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |