Controls and indicators

Assignment diagramL0

Electrical connection ratings

Rated insulation voltage Ui30 V
Rated impulse withstand voltage Uimp1.5 kV
Discrepancy time 
between FO1A and FO1Bmax. 10 ms
Utilization category 
DC-1324V 200mA 
Risk time according to EN 60947-5-3max. 350 ms
Safety classIII
Transponder codingUnicode
Degree of contamination (external, according to EN 60947-1)3
 Solenoid control input IMP1, IMP2, IMM
Test pulsesmax. 5 ms
Test pulse intervalmin. 100 ms
 Monitoring outputs OD, OT, OL, OI
Output typeSemiconductor outputs, p-switching, short circuit-proof
Output currentmax. 50 mA
Output voltageUA-2V ... UA V DC 
 Safety outputs FO1A, FO1B
Output typeSemiconductor outputs, p-switching, short circuit-proof
Output current 
per safety output FO1A / FO1B1 ... 200 mA
Output voltage 
UFO1A /UFO1B HIGHUB-2V ... UB V DC 
UFO1A /UFO1B LOW0 ... 1 V DC
Test pulsesmax. 1 ms
Test pulse intervalmin. 100 ms
 Power supply UA
Current consumption 
IUAmax. 375 mA 
Operating voltage DC 
UA24 V DC -15% ... +10% 
 Power supply UB
Current consumption 
IUBmax. 80 mA 
Operating voltage DC 
UB24 V DC -15% ... +10% 

Mechanical values and environment

ConnectionPlug connector RC18 
Degree of protectionIP65
Material 
HousingFiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Mechanical life 
 1 x 10⁶
in case of use as door stop, and 1 Joule impact energy0.1 x 10⁶
Installation orientationDoor hinge DIN right
Switching frequency0.25 Hz
Ambient temperature 
at UB = 24V DC-20 ... +55 °C
Locking force FZh2000 N
Guard locking principleOpen-circuit current principle

Reliability values acc. to EN ISO 13849-1

Mission time20 y
 Monitoring of guard locking and the guard position
Category4
Performance LevelPL e
PFHD3.7 x 10-9

Miscellaneous

Product version numberV4.0.0